• Waterproof IP67 Adjustable General-Purpose Momentary Limit Switch (WLCA12-2-Q)
  • Waterproof IP67 Adjustable General-Purpose Momentary Limit Switch (WLCA12-2-Q)
  • Waterproof IP67 Adjustable General-Purpose Momentary Limit Switch (WLCA12-2-Q)
  • Waterproof IP67 Adjustable General-Purpose Momentary Limit Switch (WLCA12-2-Q)
  • Waterproof IP67 Adjustable General-Purpose Momentary Limit Switch (WLCA12-2-Q)
  • Waterproof IP67 Adjustable General-Purpose Momentary Limit Switch (WLCA12-2-Q)

Waterproof IP67 Adjustable General-Purpose Momentary Limit Switch (WLCA12-2-Q)

Warranty: 2 Year
Brand: Manyee
Certification: CCC, CE
Contact Configuration: 2-Circuit Double Break Type
Actuator: Adjustable Roller Lever
Transport Package: 50PCS/CTN G. W: 18kgs
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
WLCA12-2-Q
Origin
China
HS Code
8536500000
Production Capacity
800000PCS/Year

Product Description

Specifications
 
ITEM Data
Rating load 10A/250VAC
Operating speed 1mm-50cm/s
Operating frequency Mechanical  120times/min
Electrical 30times/min
Insulation resistance 100MΩ(Above)DC500V
Contact resistance 25MΩ(intial value)
Withstand voltage Non-connection wire 1000VAC
Every terminal 1500VAC
Vibration Misoperation 10-55Hz Amplitude 1.5mm
Impact Durable 1000m/s²
Misoperation 300m/s²
Life Electrical 100,000above
Mechanical 1,000,000above
Protection degree IP66
Operation temperature -10~+80ºC
Operating humidity <85%
4.Operating Characteristics
 
Model WLCA-2
OF Max  1360g
RF Min 227g
PT Max  20º
OT Min 30º
MD Max  12º
EP Max 2720g
OP 50º

Switch features
 
1).N/O and N/C, brass contact, Silver tip  
2)With strong aluminum die-cast cover
3)Structure preventing oil,water and pressure
4)Indicating plate with setting position is installed in it,ao it is easy to maintain
5)Various of actuators is taken convenience for using
6)Built-in contact stand has double-spring,so it has long mechanical life
Material Aluminium body with stainless steel pin plunger
Degree of protection IP65
Mechanical 15,000,000 operations                                                                                                                                       
Rated frequency 50/60 Hz 
Protection against electric shock Class I
Ambient operating temperature  -10°C to +80°C (with no icing)
Ambient operating humidity 35% to 95% RH
Standard sensitivity, IP67, Snap action, Self-reset mechanism, 2-circuit double break type, SPST-NO / SPST-NC, Adjustable roller lever
Shape/Structure General-purpose Limit switches
Actuator Adjustable roller lever
 
Contact configuration 2-circuit double break type
Load General load
Degree of protection IEC60529 (JEM): IP67
NEMA250: Type3, 4, 13
Shape/Structure General-purpose Limit switches
Service life General type
Operating mechanism Snap action
Actuator Adjustable roller lever
Frequency 50/60 Hz
Switching mechanism Self-reset mechanism
Contact configuration 2-circuit double break type
Contact form SPST-NO / SPST-NC
Load General load
Ratings (AC): Non-Inductive load Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 1 A(NO)
Rated voltage: 500 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 0.8 A(NO)
Ratings (AC): Inductive load Rated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
Rated voltage: 500 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 4 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.8 A(NC) 0.8 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.1 A(NC) 0.1 A(NO)
Ratings (DC): Inductive load Rated voltage: 8 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO)
Rated voltage: 14 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO)
Rated voltage: 30 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 4 A(NC) 4 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.8 A(NC) 0.8 A(NO) / Motor load: 0.2 A(NC) 0.2 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO)
Inrush current NC: 30 A
NO: 20 A
Conduit size G1/2
Earth terminal Without ground terminal
Ambient temperature Operating: -10 to 80 ºC
Ambient humidity Operating: 35 to 95%
 
Permissible operating speed 1 mm/s to m/s
Permissible operating frequency (Mechanically) 120 operations / 1 minute Max.
Permissible operating frequency (Electrically) 30 operations / 1 minute Max.
Contact resistance 25 mOhm Max. (Initial value)
(Measuring method is contact resistance meter.)
Insulation resistance Between each terminal of the same polarities: null MΩ
Between live-metallic part and ground: null MΩ
Between each terminal and non-live-metallic part: null MΩ
(at 500 VDC Megger)
Dielectric strength Between each terminal of the same polarities: null V
Between live-metallic part and ground: null V
Between each terminal and non-live-metallic part: null V
(50/60 Hz for 1 min)
Durability (Mechanically) 15,000,000 operations Min. (No load)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Durability (Electrically) 750,000 operations Min. (Resistive load 10 A at 125 VAC)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Vibration resistance (Malfunction) Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
Shock resistance (Destruction) 1,000 m/s2
Shock resistance (Malfunction) Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2.
Degree of protection IEC60529 (JEM): IP67
NEMA250: Type3, 4, 13
Mounting specification Front mounting
Back mounting
 
Operating Force (OF) Standard value Max. 13.34 N
Release Force (RF) Standard value Min. 2.23 N
Pre-Travel (PT) Standard value 15 +/- 5 DEG
Over-Travel (OT) Standard value 30 DEG Min.
Movement Differential (MD) Standard value 12 DEG Max.
Condition of operating characteristics When the rod length is 38 mm
Waterproof IP67 Adjustable General-Purpose Momentary Limit Switch (WLCA12-2-Q)Waterproof IP67 Adjustable General-Purpose Momentary Limit Switch (WLCA12-2-Q)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
1001~2000 square meters
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001