Customization: | Available |
---|---|
Warranty: | 2 Year |
Brand: | Manyee |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ITEM | Data | |
Rating load | 10A/250VAC | |
Operating speed | 1mm-50cm/s | |
Operating frequency | Mechanical | 120times/min |
Electrical | 30times/min | |
Insulation resistance | 100MΩ(Above)DC500V | |
Contact resistance | 25MΩ(intial value) | |
Withstand voltage | Non-connection wire | 1000VAC |
Every terminal | 1500VAC | |
Vibration | Misoperation | 10-55Hz Amplitude 1.5mm |
Impact | Durable | 1000m/s² |
Misoperation | 300m/s² | |
Life | Electrical | 100,000above |
Mechanical | 1,000,000above | |
Protection degree | IP66 | |
Operation temperature | -10~+80ºC | |
Operating humidity | <85% |
Model | WLCA-2 |
OF Max | 1360g |
RF Min | 227g |
PT Max | 20º |
OT Min | 30º |
MD Max | 12º |
EP Max | 2720g |
OP | 50º |
1).N/O and N/C, brass contact, Silver tip |
2)With strong aluminum die-cast cover |
3)Structure preventing oil,water and pressure |
4)Indicating plate with setting position is installed in it,ao it is easy to maintain |
5)Various of actuators is taken convenience for using |
6)Built-in contact stand has double-spring,so it has long mechanical life |
Material | Aluminium body with stainless steel pin plunger |
Degree of protection | IP65 |
Mechanical | 15,000,000 operations |
Rated frequency | 50/60 Hz |
Protection against electric shock | Class I |
Ambient operating temperature | -10°C to +80°C (with no icing) |
Ambient operating humidity | 35% to 95% RH |
Shape/Structure | General-purpose Limit switches |
---|---|
Actuator | Adjustable roller lever |
Contact configuration | 2-circuit double break type |
Load | General load |
Degree of protection | IEC60529 (JEM): IP67 NEMA250: Type3, 4, 13 |
Shape/Structure | General-purpose Limit switches |
---|---|
Service life | General type |
Operating mechanism | Snap action |
Actuator | Adjustable roller lever |
Frequency | 50/60 Hz |
Switching mechanism | Self-reset mechanism |
Contact configuration | 2-circuit double break type |
Contact form | SPST-NO / SPST-NC |
Load | General load |
Ratings (AC): Non-Inductive load | Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO) Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 1 A(NO) Rated voltage: 500 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 0.8 A(NO) |
Ratings (AC): Inductive load | Rated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO) Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO) Rated voltage: 500 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO) Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO) Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 4 A(NC) 3 A(NO) Rated voltage: 125 VDC / Resistive load: 0.8 A(NC) 0.8 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO) Rated voltage: 250 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.1 A(NC) 0.1 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 8 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO) Rated voltage: 14 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO) Rated voltage: 30 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 4 A(NC) 4 A(NO) Rated voltage: 125 VDC / Inductive load: 0.8 A(NC) 0.8 A(NO) / Motor load: 0.2 A(NC) 0.2 A(NO) Rated voltage: 250 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO) |
Inrush current | NC: 30 A NO: 20 A |
Conduit size | G1/2 |
Earth terminal | Without ground terminal |
Ambient temperature | Operating: -10 to 80 ºC |
Ambient humidity | Operating: 35 to 95% |
Permissible operating speed | 1 mm/s to m/s |
---|---|
Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 30 operations / 1 minute Max. |
Contact resistance | 25 mOhm Max. (Initial value) (Measuring method is contact resistance meter.) |
Insulation resistance | Between each terminal of the same polarities: null MΩ Between live-metallic part and ground: null MΩ Between each terminal and non-live-metallic part: null MΩ (at 500 VDC Megger) |
Dielectric strength | Between each terminal of the same polarities: null V Between live-metallic part and ground: null V Between each terminal and non-live-metallic part: null V (50/60 Hz for 1 min) |
Durability (Mechanically) | 15,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Durability (Electrically) | 750,000 operations Min. (Resistive load 10 A at 125 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s2 |
Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. |
Degree of protection | IEC60529 (JEM): IP67 NEMA250: Type3, 4, 13 |
Mounting specification | Front mounting Back mounting |
Operating Force (OF) | Standard value Max. 13.34 N |
---|---|
Release Force (RF) | Standard value Min. 2.23 N |
Pre-Travel (PT) | Standard value 15 +/- 5 DEG |
Over-Travel (OT) | Standard value 30 DEG Min. |
Movement Differential (MD) | Standard value 12 DEG Max. |
Condition of operating characteristics | When the rod length is 38 mm |