• Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)
  • Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)
  • Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)
  • Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)
  • Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)
  • Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)

Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)

Warranty: 2 Year
Brand: Manyee
Operation: Automatic or Manual
Certification: CCC, CE, ISO9001
Type: Integrated automatic transfer switch
Poles: 3p or 4p
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
QKGLD-250
Output type
Dual
Frame Current
250A
Rated Working Voltage
400VAC
Protection Function
Phase Detection Protection
Application
Hospital, Shopping Malls, Banks, etc.
Rated Insulation Voltage
to 1000V
Rated Frequency
50/60Hz
Transport Package
Export Standard Carton
Specification
250A
Origin
China
HS Code
8536500000
Production Capacity
1000000 PCS/Year

Product Description

Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)Product Overview
QKGLD Automatic Transfer Switch (ATSE) is an automatic transfer switch that integrates switch and logic control, without the need for an external controller, and truly realizes mechatronics, with voltage detection, frequency detection, communication interface, electrical, mechanical interlock and other functions, which can realize automatic, electric remote and emergency manual control.
The operation is realized by the logic control board to manage the operation of the motor and gearbox with various logic commands. The motor is an acceleration mechanism with a switching spring to store energy and release it instantaneously, and quickly switch on the circuit breaker or switch the circuit, and achieve safety isolation through a clearly visible state, which significantly improves the electrical and mechanical properties.
The QKGLD automatic transfer switch is designed as a plastic and metal housing, which is compact and robust. The control part of the QKGLD switch is made of plastic and metal housing. Its switch part is made of glass fiber unsaturated polyester resin, which has strong dielectric properties, protection capabilities and reliable operational safety.
This switch is suitable for the automatic conversion of the main power supply and the standby power supply of the power supply system or the automatic conversion and safety isolation of two load equipment.
This switch is beautiful, novel, concise, small in size, and full in function, making it the best choice for similar products.
Executive Standard
The dual power supply complies with IEC 60947-6-1 and GB 14048.11 Low-Voltage Switchgear and Control Equipment - Part 6: Multifunctional Appliances - Part 1 Automatic Transfer Switching Appliances.
Features:
It adopts double-row composite contact, horizontal pull mechanism, micromotor pre-energy storage and microelectronic control technology, and basically realizes zero flying fox (no arc extinguishing cover);
It adopts reliable mechanical interlocking and electrical interlocking, and adopts independent load isolation switch without components, which is safe and reliable to use;
It adopts zero-crossing technology, which can be forced to set zero in case of emergency (cut off two power supplies at the same time) to meet the needs of fire linkage;
The load isolation switch is driven by a single motor, and the switching is reliable and stable, noiseless and the impact force is small;
The operator drive motor only passes the current at the moment of load isolation switch switching, and there is no need to provide working current for steady-state operation, which saves significant energy.
The actuator load isolation switch is equipped with a mechanical interlock device, which ensures that the common and standby power supplies work reliably and do not interfere with each other;
It is equipped with obvious on-off position indication, padlock and other functions, and reliably realizes the isolation between the power supply and the load;
It has good safety performance, high degree of automation, high reliability, and a service life of more than 8,000 times;
It adopts mechatronics design, and its switching conversion is accurate, flexible and smooth. In addition, it adopts international advanced logic control technology, which enables it to have strong anti-interference ability and no external interference;
It has three kinds of stable operation (I-0-II.) of main power supply and standby power supply, main power supply and standby power supply, and disconnection of main and standby power supply (I-0-II.);
It is easy to install, and the control loop is connected by pluggable terminals;
Four operation functions: emergency manual operation, electric remote control operation, emergency disconnection operation in automatic control state, and automatic control operation.
Applications
QKGLD series automatic transfer switch is mainly used for AC 50Hz, rated voltage 400V, DC rated voltage 220V, rated current 16A to 3200A in the distribution or motor network of one main and one standby or mutual standby power switching system and the load switching of mains and generator sets. At the same time, it can be used for infrequent switching and breaking circuits and line isolation.
This product is extensively applies in power transmission and distribution systems and automation systems in important power supply places such as fire protection, hospitals, banks, and high-rise buildings that do not allow power outages.
Operation Environment
Automatic transfer switches work reliably under the following conditions:
The altitude does not exceed 2000 meters;
The ambient temperature is not higher than 40°C, not lower than -5°C, and the relative humidity is not more than 95%;
No explosion hazard medium environment;
No rain and snow invade the environment;
Note: If it is expected to be suitable for the ambient air temperature above +40°C or below -5°C~-45°C, the user should explain to the manufacturer.
Intelligent Performance
1. Three kinds of stable working positions:
Common closing: common closing, standby opening. Standby closing: common opening, standby closing. Double opening: common opening, standby opening.
2. Two optional automatic working modes
Automatic charge and automatic recovery: when the standby power is closed and the common power supply returns to normal, the switch will automatically switch to normal closure regardless of whether the standby power supply is normal.
Automatic charge and manual recovery: when the standby power is closed and the common power supply returns to normal, and the standby power supply is normal, the switch does not convert, only when the standby power supply is abnormal, the switch will automatically switch to normal.
3. Four conversion control modes
Automatic control: The controller automatically converts to the appropriate working position according to the current voltage condition and the set working mode.
Manual control: when the power supply is normal, the switch can be converted to any working position by pressing the button.
Manual control: After the key is hit to the manual position, it can be operated manually with the handle.
Remote control: Through the remote programmable input signal or 485 communication port, the control switch is switched to the required working position.
4. Product function: real-time monitoring and display of operating parameters, real-time transfer switch position and alarm. Under-voltage, over-voltage, and phase loss protection functions prevent the faulty power supply from supplying power to the load. Self-diagnosis and fault alarm function.
5. Optional functions: fire double opening alarm, automatic control of power generation, two sets of programabe signal output elays, power indication, communiction
 

Main Technical Parameters:
1. Usage Category: AC-33B, Typical use is infrequent operation of motor loads or mixed loads containing motors, resistive loads, and incandescent lamp loads of less than 30%.
2. Rated frequency: 50Hz.
3. Other technical parameters are shown in Table 1.
Agree on the heating current Ith 20A 40A 63A 80A 100A 125A 160A 250A 400A 630A 800A 1000A 1250A 1600A
Rated insulation voltage Ui 750V 1000V
Rated impulse withstand voltage Uimp 8KV 12KV
Rated operating voltage Ue AC440V
Rated working current Ie AC-31A 20 40 63 80 100 125 160 250 400 630 800 1000 1250 1600
AC-35A 20 40 63 80 100 125 160 250 400 630 800 1000 1000 1600
AC-33A 20 40 63 80 100 125 160 250 400 400 630 800 800 1000
Rated turn-on capacity 10Ie
Rated breaking capacity 8Ie
Rated to limit short-circuit current 100KA 70KA 100KA 120KA
Rated short-time withstand current 1S 7KA 9KA 13KA 26KA 50KA
Conversion time I.- II or II.- I. 0.45S 0.6S 1.2S
Control the power supply voltage DC24V, 48V, 110V           AC220V
Motor energy consumption  
Rated control voltage Initiate 300W 325W 355W 400W 440W
Normal 55W 62W 74W 90W 98W
Weight (kg) 4 poles 7.0 7.2 7.2 7.2 7.5 7.5 8.8 9.0 16.5 17 32 36 40 43
Integrated Automatic Changeover Switch with LCD Display Control (QKGLD-250)
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
1001~2000 square meters
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001