• Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)
  • Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)
  • Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)
  • Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)
  • Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)
  • Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)

Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)

Warranty: 2 Year
Operation: Rotating Handle
Certification: CCC, CE
Type: General-Purpose Limit Switch
Contact Configuration: 2-Circuit Double Break Type
Actuator: Adjustable Roller Lever
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
WLD2
Protection
IP67
Transport Package
50PCS/CTN G. W: 18kgs
Trademark
MANYEE
Origin
China
HS Code
8536500000
Production Capacity
8000000pieces/Year

Product Description

Double-circuit limit switch.is widely used.
Firm aluminum alloy enclosure.
High mechanical strength.
Structure preventing oil,water and pressure.
Indicating plate with setting position is installed in it,so it is easy to    maintain.
 Kinds of actuators is taken convenience for using.
 Built-in contact stand has double-reed,so it has long mechanical life.
 
Specification
 
Item Data
Rating load 5A/250VAC
Operating speed 1mm-1m/s
Operating frequency Mechanical 120times/min
Electrical 30times/min
Insulation resistance 100MΩ(Above)DC500V
Contact resistance 25MΩ(intial value)
Withstand voltage Non-connection wire 1000VAC
Every terminal 1500VAC
Vibration Misoperation 10-55Hz Amplitude 1.5mm
Impact Durable 1000m/s²
Misoperation 300m/s²
Life Electrical 100,000above
Mechanical 1,000,000above
Pertection degree IP65
Operating temperature -10'C~80'C
Operating humidity  ≤ 95%
 
odel WLCA-2 WLD2 WLNJ WLNJ-S2 WJCA12-2-Q WLCL WLCA32-41 WLD WLNJ-2 WLNJ-30 WLD1 WLD3
OF(Max) 1360g 2720g 150g 29g 1360g 142g 1200g 2720g 120g 80g 2720g 2720g
RF(Min) 227g 910g     227g 28g   910g     910g 910g
PT(Max) 20º 20º 20º 1.5mm 1.5mm 30mm   1.7mm 28mm 28mm 1.7mm 1.7mm
OT(Min) 30º 50º 50º 4mm 4mm     6.4mm     5.6mm 5.6mm
MD(Max) 12º 12º 12º 1mm 1mm     1mm     1mm  
EP(max) 2720g                   2720g  
OP 50º  

65mm±

0.8mm

  50º 50º

OP90±

10º

 

OP34±

2.8mm

 

65mm±

0.8mm

9mm±

0.8mm
 


Outline And Installation Dimensions
 
OF Max 2720g
RF Min 910
PT Max 1.7mm
OT Min 6.4mm
MD Max 1mm
EP --
OP --
Standard sensitivity, IP67, Snap action, Self-reset mechanism, 2-circuit double break type, SPST-NO / SPST-NC, Top roller plunger
Shape/Structure General-purpose Limit switches
Actuator Top roller plunger
17 dia. * 5 Sintered stainless steel roller
Contact configuration 2-circuit double break type
Load General load
Degree of protection IEC60529 (JEM): IP67
NEMA250: Type3, 4, 13
Shape/Structure General-purpose Limit switches
Service life General type
Operating mechanism Snap action
Actuator Top roller plunger
17 dia. * 5 Sintered stainless steel roller
Frequency 50/60 Hz
Leakage current Approx. 0.5 mA
Switching mechanism Self-reset mechanism
Contact configuration 2-circuit double break type
Contact form SPST-NO / SPST-NC
Load General load
Ratings (AC): Non-Inductive load Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 1 A(NO)
Rated voltage: 500 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 0.8 A(NO)
Ratings (AC): Inductive load Rated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
Rated voltage: 500 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 4 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.8 A(NC) 0.8 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.1 A(NC) 0.1 A(NO)
Ratings (DC): Inductive load Rated voltage: 8 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO)
Rated voltage: 14 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO)
Rated voltage: 30 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 4 A(NC) 4 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.8 A(NC) 0.8 A(NO) / Motor load: 0.2 A(NC) 0.2 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO)
Inrush current NC: 30 A
NO: 20 A
Conduit size G1/2
Earth terminal Without ground terminal
Ambient temperature Operating: -10 to 80 ºC
Ambient humidity Operating: 35 to 95%
 
Permissible operating speed 1 mm/s to 0.5 m/s
Permissible operating frequency (Mechanically) 120 operations / 1 minute Max.
Permissible operating frequency (Electrically) 30 operations / 1 minute Max.
Contact resistance 25 mOhm Max. (Initial value)
(Measuring method is contact resistance meter.)
Insulation resistance Between each terminal of the same polarities: null MΩ
Between live-metallic part and ground: null MΩ
Between each terminal and non-live-metallic part: null MΩ
(at 500 VDC Megger)
Dielectric strength Between each terminal of the same polarities: null V
Between live-metallic part and ground: null V
Between each terminal and non-live-metallic part: null V
(50/60 Hz for 1 min)
Durability (Mechanically) 15,000,000 operations Min. (No load)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Durability (Electrically) 750,000 operations Min. (Resistive load 10 A at 125 VAC)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Vibration resistance (Malfunction) Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
Shock resistance (Destruction) 1,000 m/s2
Shock resistance (Malfunction) Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2.
Degree of protection IEC60529 (JEM): IP67
NEMA250: Type3, 4, 13
Mounting specification Front mounting
Back mounting
 
Operating Force (OF) Standard value Max. 26.67 N
Release Force (RF) Standard value Min. 8.92 N
Pre-Travel (PT) Standard value 1.7 mm Max.
Over-Travel (OT) Standard value 5.6 mm Min.
Movement Differential (MD) Standard value 1 mm Max.
Operating Position (OP) Standard value 44 +/- 0.8 mm
Operating limit position (TTP) Standard value 39.5 mm Max.
Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)
Standard Sensitivity Snap Actionoller Plunger Type Mechanism Limit Switch (WLD2)






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
1001~2000 square meters
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001